RELIANCE ELECTRIC MOTOR DATA
COMPILED FROM THE SUBMERSIBLE
MOTOR ACTION GUIDE

THREE PHASE 1150 RPM (6 POLE) MOTORS

Pg ED-2

HP (1)

RPM

NEMA DESIGN CODE

LOCKED ROTOR CODE

WT

FRAME

FULL LOAD AMPS

FULL LOAD

COIL RESISTANCE

CABLE SIZE

230V

480V

PF

EFF

230V

480V

230V

480V

.5
.75
1

1150

*
*
B

M
J
J

200

140TY Mount

2.6
3.2
3.6

1.3
1.6
1.8

63.8
72.6
78.4

59.0
62.8
66.4

5.9
5.9
4.19

23.6
23.6
16.7

14

14

1.5
2
3

1150

*
B
B

J
J
H

165
200
200

140TY Mount
180TY

6.2
6.8
10.4

3.1
3.4
5.2

66.7
75.7
69.3

69.0
72.8
78.0

2.82
2.52
1.28

11.3
10.1
5.13

14

14

5
7.5
10

1150

B

G
G
H

200
335
335

180TY
210TY
210TY

15.2
23.0
31.0

7.6
11.5
15.5

80.3
77.7
78.3

76.2
78.1
76.5

1.3
.54
.40

4.11
2.17
1.59

12
10
8

14
14
12

15
20
25

1150

B

G

445

250TY

39.0
54.0
68.0

19.5
27.0
34.0

84.4
82.7
81.9

84.4
84.0
83.3

.25
.18
.13

1.00
.77
.53

8
6
4

10
8
8

30
40
50

1150

B

G
G
F

1150

320TY

80.0
106.6
-

40.0
53.3
63.0

80.9
80.0
84.2

86.9
87.7
88.2

.10
.08
-

.36
.30
.227

2
2
1/0

8
6
4

60
75
100
125

1150

B

F
G
G

F

1150
1500
1500

1500

320TY
360TY
360TY

360TY

154.0
NA
NA

NA

77.0
90.9
122.0

148.0

83.1
83.8
84.2

86.2

88.0
92.3
91.2

91.8

.04
NA
NA

NA

.17
.121
.0
878
.07

2\0
NA
NA

NA

2
2
1

2/0

(1) MOTOR RATINGS ABOVE 60 HP ARE NOT AVAILABLE IN VOLTAGES BELOW 460 VOLTS.
  • MULTIPLY 230 VOLT AMPERAGE IN TABLE ABOVE BY 1.15 TO GET FULL LOAD AMPERAGE AT 208 VOLTS.
  • CONTROL CABLE FOR ALL MOTOR IS .485+/-.025 INCH DIAMETER, CONDUCTOR IS 18/5
  • WHEN MOTORS ARE ORDERED AT 460 VOLT CONNECTION ONLY, MOTORS ARE NOT RECONNECTABLE TO 230 VOLT.
  • CONSULT FACTORY FOR CABLE LENGTHS GREATER THAN 95 FEET